Cov modular contactors yog muab rau koj los ntawmCDADA, tus neeg muag khoom txhim khu kev qha thiab ntseeg siab. Raws li cov chaw tsim khoom ncaj qha, peb muaj ntau tshaj 15 xyoo ntawm kev paub tshwj xeeb nrog cov khoom lag luam no. Tsis tas li ntawd, peb tag nrho cov khoom siv hluav taws xob tsis tshua muaj hluav taws xob-tsim tau ntau xyoo-ib txwm muab cov khoom lag luam zoo thiab lub neej ntev tshwj xeeb; Yog tias koj ntsib teeb meem, koj tuaj yeem tiv tauj peb txhua lub sijhawm rau kev txhawb nqa tom qab muag.
A modular contactor yog ib qho compact, DIN rail-mounted electromechanical switching ntaus ntawv tsim tshwj xeeb rautsev installation thiab kev siv hauv tsev. Tsis zoo li kev lag luam contactors tswj hwm los ntawm IEC 60947-4-1, modular contactors ua rawsIEC 61095 (TSI) (TSI)-tus qauv nrog "cov kev cai nruj heev, ua tau raws li qhov xav tau ntawm cov neeg siv khoom, hais txog kev nyab xeeb ntawm cov khoom siv thiab cov neeg nyob hauv thaj chaw thiab thaj chaw nkag tau rau pej xeem".
Cov cuab yeej no muaj qhov astandardized modular dav (ntau yam ntawm 17.5mm) ua kom muaj kev sib txuam tsis sib haum rau hauv cov vaj huam sib luag faib ib sabMCBs, RCDs, thiab lwm yam khoom siv modular. Cov kev ntsuas tam sim no muaj los ntawm16A rau 100A, nrog coil voltages spanning12V DC rau 240V AC (xws li AC / DC universal coils), ua rau lawv zoo tagnrho rau kev hloov cov teeb pom kev zoo, cua sov, qhov cua, thiab cov cav me me hauv cov tsev nyob, kev lag luam, thiab kev ua liaj ua teb.
Qhov tseebIEC 61095 (TSI) (TSI): 2023 Tsab ntawv 3.0 qhia txog cov kev cai tshiab rau LED teeb pom kev zoo loads (AC-7d), txhim kho EMC kev tiv thaiv, thiab nruj dua daim ntawv lo raws tu qauv-xav txog kev hloov pauv mus rau lub tsev ntse thev naus laus zis thiab kev tswj hwm lub zog.
|
Kev faib tawm |
Hom |
Ntau yam tam sim no |
Cov yam ntxwv tseem ceeb |
|
Kev siv qeb |
AC-7 ua |
16A – 100A |
Ib me ntsis inductive loads: khoom siv hauv tsev, cua sov, resistive loads (cos φ 0.8) |
|
AC-7b |
16A – 63 A |
Lub cev muaj zog: squirrel-cage motors, cua txias, twj tso kua mis (cos φ 0.45) |
|
|
AC-7d |
16 A-32 A |
IEC 61095 (TSI) (TSI): 2023 LED teeb pom kev zoo (tshiab hauv IEC 61095: 2023), kev sib haum xeeb-nplua nuj |
|
|
Ncej Configuration |
2-Pole (2NO) |
16A – 100A |
Ib theem hloov, cua sov / teeb pom kev zoo, feem ntau configuration |
|
2-Pole (1NO + 1NC) |
16A - 40A |
Hloov cov ntawv thov, dual-ceev kiv cua, thim rov qab motors |
|
|
4-Pole (4NO) |
16A – 100A |
Peb-theem + nruab nrab, peb-theem cua sov, me me peb-theem motors |
|
|
4-Pole (2NO + 2NC) |
16A - 40A |
Hloov pauv hloov, hloov lub tshuab hluav taws xob, muab ob npaug |
|
|
Coil Technology |
AC Coil |
24V, 110V, 220-240V |
Standard 50/60Hz, audible hum thaum ua haujlwm |
|
DC Coil |
12 V, 24 V |
Kev ua haujlwm ntsiag to, lub roj teeb rov qab, tswj cov kab hluav taws xob |
|
|
AC / DC Universal |
24-240V (tsis siv neeg hloov) |
Hum-dawb ua haujlwm, dav voltage kam rau ua, txo cov khoom muag |
|
|
Electronic Coil |
12-240V AC / DC |
Tsawg noj (2-4VA), surge tiv thaiv kev sib xyaw, ntsiag to |
|
|
Mounting |
DIN Rail (TH35) |
Txhua qhov kev ntsuas |
35mm sab saum toj-lub kaus mom rail, snap-on installation, IP20 ntiv tes-kev nyab xeeb |
|
Vaj huam sib luag Mount |
16A – 100A |
Screw-taw puag, tiaj tus mounting, tiv thaiv kev vibration |
|
|
Npog |
Qhib (IP20) |
Txhua qhov kev ntsuas |
Standard modular tsim, faib vaj huam sib luag mounting |
|
Npog (IP40-IP65) |
16A – 63 A |
Built-in enclosure, plua plav / noo noo tiv thaiv, siv sab nraum zoov |
Modular Width Standards:
1 Module (17.5 hli): 16A-25A, 2-ncej
2 Module (35 hli)40A-63A, 2/4-ncej
3-4 Module (52.5-70mm):80A-100A, kev siv hluav taws xob siab
|
Cheebtsam |
Muaj nuj nqi |
Technical Specification |
|
Electromagnetic Chev |
Tsim magnetic teb rau kev sib cuag kaw |
AC: 24V, 110V, 220-240V (50/60Hz); DC: 12V, 24V; AC / DC: 24-240V universal; 4-8V (AC), 2-4W (DC) |
|
Laminated Core |
Concentrates magnetic flux, txo eddy tam sim no |
Silicon steel E-core, qhov chaw rwb thaiv tsev, tsis tshua muaj siab |
|
Movable Armature |
Hloov magnetic quab yuam los tiv thaiv tus choj |
Caij nplooj ntoos hlav-rov qab, tiv thaiv bounce tsim, <20ms teb |
|
Cov neeg tseem ceeb |
Nqa lub zog hluav taws xob tam sim no |
Silver-nickel (AgNi) lossis silver-cadmium oxide (AgCdO), ob chav so so ua haujlwm |
|
Hu rau Choj |
Mechanically txuas ncej teeb, ua kom muaj kev ua haujlwm ib txhij |
Copper alloy, yoog raws kev sib txuas, nws tus kheej-aligning |
|
Arc Chute |
Quenches tawg arc (AC-7b daim ntawv thov) |
Ceramic splitter daim hlau, deionizing daim phiaj, sib nqus tshuab |
|
Kev Sib Txuas Sib Txuas |
Control, signaling, interlocking (yeem) |
1NO + 1NC lossis 2NO, 10A kev ntsuas, snap-action |
Coil Energization - Tswj voltage siv rau coil terminals (A1-A2)
Magnetic Field Generation - Tam sim no tsim electromagnetic flux hauv laminated core
Armature Attractions -Magnetic quab yuam overcomes lub caij nplooj ntoos hlav siab, armature txav
Hu rau Kaw - Kev sib cuag txuas txuas txuas nrog kev sib txuas ruaj khov nrog kev tshem tawm (kev tu tus kheej)
Kev ua tiav Circuit Court - Fais fab ntws los ntawm kab terminals (L) mus thauj khoom terminals (T)
Coil De-energization - Tswj voltage tshem tawm
Field Collapse - Sib nqus flux decays (AC: xoom-hla; DC: freewheeling diode)
Caij nplooj ntoos hlav rov qab los - Rov qab springs tsav armature rau qhib txoj hauj lwm
Sib cais - Arc pib (yog tias nyob rau hauv load), kos rau hauv arc chute
Arc Extinction - AC arc self-extinguishes ntawm xoom tam sim no; DC arc quenched los ntawm splitter daim hlau
Niaj hnub nimno modular contactors feature tshiab AC / DC coil tsim uas tshem tawm cov yam ntxwv 50/60Hz hum:
Duplex winding tshuab: Sib cais AC thiab DC coils nrog hluav taws xob hloov
Universal voltage input: Nws pib-nrhiav AC lossis DC mov, kho hom kev ua haujlwm
Ua haujlwm ntsiag to: Zoo tagnrho rau chav tsev so, tsev kho mob, chav pw hauv tsev, thiab qhov chaw muaj suab nrov
Txo kev siv hluav taws xob: 50% qis tuav lub zog piv rau cov pa AC coils
|
Daim ntawv thov |
Kev siv tshwj xeeb |
Hom Specifications |
Kev siv qeb |
|
Kev tswj teeb pom kev zoo |
LED teeb pom kev zoo, fluorescent teeb, tso tawm teeb |
16A-32A, 2NO, AC-7d (LED), AC-7a (tso tawm), 230V coil |
AC-7a / AC-7d |
|
Cua sov Systems |
Electric boilers, cia cua sov, underfloor cua sov |
25A-63A, 2NO lossis 4NO, AC-7a, 230V kauj, ua haujlwm ntsiag to nyiam |
AC-7 ua |
|
Qhov cua & HVAC |
Extractor kiv cua, cua tuav units, cua txias tshuab |
16A-40A, 2NO, AC-7b (lub cev muaj zog), 230V coil, siab hloov zaus |
AC-7b |
|
Cov Khoom Siv Hluav Taws Xob |
Cov menyuam shutters, chaw nres tsheb qhov rooj, rooj vag, awnings |
16A-25A, 2NO lossis 1NO + 1NC, AC-7b, 24V DC tswj (kev nyab xeeb ntxiv-tsawg voltage) |
AC-7b |
|
Cov twj tso kua mis |
Booster twj, twj tso kua mis, twj zoo |
16A-32A, 2NO, AC-7b, 230V coil, twj tso kua mis lub luag hauj lwm ntsuas |
AC-7b |
|
Kev Tswj Xyuas Zog |
Load shedding, ncov shaving, dual-tariff switching |
40A-100A, 4NO, AC-7a, 230V coil nrog timer / lub zog ntsuas ntsuas |
AC-7 ua |
|
Lub zog tauj dua tshiab |
Hnub ci PV hloov, roj teeb cia, EV them |
25A-63A, 4-ncej, DC coil los yog AC / DC universal, ncua qhov kub thiab txias |
AC-7a / AC-7b |
|
Kev ua liaj ua teb |
Irrigation twj, cua kiv cua, grain ziab |
25A-63A, IP65 enclosure, tropicalized, 400V peb-theem |
AC-7a / AC-7b |
Daim ntawv thov dual-tariff: Modular contactors pab kom tsis siv neeg hloov ntawm nruab hnub / hmo ntuj tus nqi hluav taws xob rau:
Cia cov cua sov (them thaum tawm ntawm lub ncov, tso tawm thaum lub siab tshaj)
Cov cua kub cua sov (rhuab thaum tus nqi pheej yig, tswj qhov kub thiab txias)
EV them (kev pib qeeb rau cov nqi qis tshaj)
Raw Khoom IQC → Laminated Core Stamping → Coil Winding & Impregnation → Sib cuag System Fabrication → Arc Chute Assembly → Mechanism Integration → Modular Housing Molding → Final Assembly → Calibration & Test → Ntim
|
Theem |
Txheej txheem txheej txheem |
Cov ntsiab lus tswj tau zoo |
|
Laminated Core Ntau Lawm |
Silicon steel ntawv (0.35-0.5mm) nce qib tuag stamping, annealing ntawm 750-800 ° C hauv hydrogen cua, rwb thaiv tsev txheej, stacking & riveting |
Core poob <3 W / kg ntawm 1.5T, rwb thaiv tsev tsis kam> 100MΩ, sib nqus permeability> 5000 |
|
Coil Winding |
Enameled tooj liab hlau (0.1-0.4mm), automated winding nrog nro tswj, lub tshuab nqus tsev vacuum impregnation (polyester lossis epoxy) |
Hloov ± 1%, DC tsis kam ± 5%, dielectric zog 2kV / 1min, impregnation uniformity |
|
AC / DC Universal Coil los ua ke |
Dual winding configuration, hluav taws xob hloov Circuit Court, surge tiv thaiv kev koom ua ke, encapsulation |
Nws pib-hloov pov thawj 24-240V, tuav lub zog <4VA, ua haujlwm ntsiag to <30dB |
|
Hu rau Fabrication |
Silver-nickel (AgNi 90/10) tiv tauj cov lus qhia, brazing rau tooj liab nqa, nce qib stamping, so geometry sib sau |
Hardness HV 80-120, tiv tauj <5mΩ, brazing zog> 50MPa |
|
Modular Tsev Moulding |
Kev cuam tshuam cov thermoplastic siab (PA66 GF30 lossis PBT GF30), 280-320 ° C txhaj tshuaj, 17.5mm suab qhov tseem ceeb |
Dimensional kam rau ua ± 0.05mm, nrhiav qhov ntsuas> 600V, UL 94 V-0, kub tsis kam 160 ° C |
|
Mechanism Assembly |
Caij nplooj ntoos hlav steel them system, toggle mechanism, DIN rail clip kev koom ua ke, kov kev sib txuas |
Mechanical endurance 100,000 cycles, tiv tauj siab sib xws, snap-on quab yuam 50-100N |
|
Calibration kawg |
Pickup voltage (0.85-1.1 × Us), poob tawm voltage (> 0.2 × Us), coil noj, tiv tauj lub sijhawm |
100% automated xeem, cov ntaub ntawv logging, QR code traceability |
|
Cheebtsam |
Khoom Specification |
Tus qauv tsim khoom |
Cov khoom tseem ceeb |
|
Laminated Core |
Grain-oriented silicon steel 35W300 lossis 50W470 (0.35-0.5mm) |
IEC 60404-8-7, JIS C 2552 |
Core poob 2.3-3.0 W / kg ntawm 1.5T, siab permeability, tsis tshua muaj magnetostriction |
|
Coil Hlau |
Enameled round tooj liab hlau, Chav F (155 ° C) lossis Chav H (180 ° C) |
IEC 60317, NEMA MW 35 |
Kev tawg voltage> 2kV, solderability 390 ° C / 2s, yooj |
|
AC / DC Electronic Module |
PCB nrog SMD Cheebtsam, varistor, choj rectifier, MOSFET hloov |
IEC 60721-3-3, IEC 61000 Kev Ua Haujlwm Zoo |
Dav voltage ntau 24-240V, surge tiv thaiv, EMC tiv thaiv qib 3 |
|
Cov neeg tseem ceeb |
Silver-nickel (AgNi 90/10) los yog silver-cadmium oxide (AgCdO) |
ASTM B152, IEC 60368, Kev Tswj Xyuas Zoo |
Conductivity ≥100% IACS, arc yaig tsis kam, tiv thaiv vuam |
|
Hu rau Choj |
Copper alloy (CuCr1Zr lossis CuNi2Si), nyiaj-plated |
ASTM B 187 Cov khoom siv |
High conductivity, caij nplooj ntoos hlav zog, hnav tsis kam |
|
Arc Chute phaj |
Steatite ceramic los yog alumina (Al₂O₃ 95%) |
IEC 60672: Ua |
Thaum tshav kub kub tsis kam> 1000 ° C, dielectric zog> 15kV / mm |
|
Modular Tsev |
PA66 GF30 (30% iav fiber) los yog PBT GF30 |
IEC 60664-1, UL 94 V-0 |
Kev ntsuas qhov ntsuas> 600V, cuam tshuam lub zog> 7 kJ / m², 17.5mm modularity |
|
DIN Rail Clip |
Lub caij nplooj ntoos hlav steel 65Mn lossis stainless hlau 304, zinc-plated |
GB/T 1222, ISO 3506 |
Clamp quab yuam 50-100N, qaug zog lub neej> 10,000 cycles, corrosion kuj |
|
Terminals |
Brass C36000 los yog tooj liab C11000 nrog tin plating (5-8μm) |
ASTM B16 / B187 Kev ntsuas |
Tam sim no ceev 1.0-1.2 A / mm², torque withstand 1.5-2.5Nm |
|
Rov qab Springs |
Roj-tempered carbon steel SWOSC-V lossis stainless hlau 301 |
JIS G 3560, ASTM A313 |
Tensile zog 1800-2200MPa, qaug zog lub neej> 100,000 cycles |
|
Txuj |
Scope |
Kev ntsuas ntsuas |
|
IEC 61095 (TSI) (TSI): 2023 (Tshooj 3.0) |
Electromechanical contactors rau tsev neeg thiab cov hom phiaj zoo sib xws |
Tus txheej txheem tseem ceeb rau cov neeg tiv thaiv modular, nruj kev nyab xeeb yuav tsum muaj rau cov pej xeem nkag mus tau |
|
IEC 60947-4-1: Cov. Cov |
Contactors thiab lub cev muaj zog pib - Electromechanical contactors |
Cov txheej txheem kev lag luam, kuj tseem siv tau rau cov neeg siv hluav taws xob ntau dua tam sim no |
|
IEC 60947-5-1 Cov |
Tswj cov khoom siv hluav taws xob thiab hloov cov khoom siv |
Kev pabcuam kev sib cuag, tswj kev ua haujlwm |
|
GB/T 17885 |
Suav teb tus qauv sib npaug |
CCC daim ntawv pov thawj, Tuam Tshoj ua lag luam |
IEC 61095 (TSI) (TSI): Kev nyab xeeb nruj dua rau tsev neeg / pej xeem thaj chaw, kev siv pawg AC-7a / AC-7b / AC-7d, yuav tsum tiv thaiv tus ntiv tes IP20
IEC 60947-4-1: Cov.Muaj kev tsom xam, kev siv pawg AC-1 / AC-3, ntau dua tam sim no, kev xeem sib txawv
|
Qeb xeem |
Kev Xeem Tshwj Xeeb |
Kev lees txais |
|
Khoom siv tau zoo |
Kev laus ua haujlwm (70 ° C / 168h), av noo (40 ° C / 93% RH / 96h), kub tsis kam (pob-siab 125 ° C) |
Tsis muaj kab nrib pleb, tsis muaj deformation <2 hli, lub zog dielectric tswj |
|
Mechanical Integrity |
Terminal zog (torque cycling), cuam tshuam tsis kam (0.5J pendulum / 2J kheej kheej), ntsia hlau durability |
Tsis muaj kev puas tsuaj, tsis muaj loosening, IP ntsuam xyuas tswj |
|
Kub nce |
Nruam tam sim no ntawm rated Nyob rau hauv, terminals hauv huab cua dawb |
Terminals ≤65K (liab qab), ≤80K (plated), enclosure ≤40K |
|
Dielectric Properties |
Fais fab zaus tiv taus (2kV-2.5kV / 1min), impulse withstand (4kV-6kV) |
Tsis tawg, tsis muaj flashover, to tam sim no <2mA |
|
Ua & tawg muaj peev xwm |
AC-7a: 1.5 × Hauv kev ua / tawg; AC-7b: 8 × Hauv kev ua, 1 × Hauv kev tawg |
Kev ua tau zoo, tsis muaj kev sib cuag vuam, tsis muaj flashover |
|
Kev ua haujlwm zoo |
Mechanical: 100,000 cycles; Hluav taws xob: AC-7a 10,000 cycles, AC-7b 5,000 cycles |
<5% parameter drift, hu rau hnav <50% |
|
Overcurrent Nrog |
6 × Hauv rau 30s (AC-7a), 10 × Hauv rau 30s (AC-7b) |
Tsis muaj kev sib cuag vuam, ua haujlwm tom qab txias |
|
Short-Circuit Coordination |
Kuaj nrog SCPD, 1kA-10kA yav tom ntej tam sim no |
Tsis muaj kev puas tsuaj, tsis muaj kev phom sij rau tus neeg teb xov tooj |
|
Ib puag ncig |
EMC kev tiv thaiv (ESD 8kV, RF 3V / m, tawg), kub tsis zoo / hluav taws kub (glow-wire 960 ° C) |
Ua haujlwm thaum / tom qab kuaj, tsis muaj hluav taws xob |
|
Khoom siv |
Cov khoom soj ntsuam |
Sampling Plan |
Khoom siv |
|
Silicon steel ntawv |
Core poob, permeability, rwb thaiv tsev txheej, thickness |
Ib pawg, COA + kuaj |
Epstein ncej, ib daim ntawv tester |
|
Enameled hlau |
Txoj kab uas hla, tawg voltage, elongation, solderability |
TSI 0.65 |
Micrometer, dielectric tester |
|
Thermoplastic granules |
Cov ntsiab lus iav, viscosity, noo noo, flammability |
Rau batch |
Melt flow indexer, DSC, UL 94 apparatus |
|
Nyiaj tiv tauj tswv yim |
Purity, ntom, hardness, brazing zoo |
Rau batch |
Spectrometer, hardness tester |
|
Cov khoom siv hluav taws xob |
Function test, parameter verification, firmware version |
100% AOI |
LCR ntsuas, oscilloscope |
|
Chaw nres tsheb |
Tswj Parameters |
Ntau zaus |
Txoj kev |
|
Core stamping |
Dimensional kam rau ua ± 0.02mm, burr <0.01mm |
Txhua 30 feeb |
Optical piv, micrometer |
|
Coil winding |
Hloov suav, nro, tsis kam, rwb thaiv tsev |
Txhua chav |
Automated winding nrog cov lus qhia |
|
AC / DC module programming |
Voltage ntau yam, hloov chaw pib, noj |
Txhua chav |
Programmable fais fab mov, cov ntaub ntawv teev tseg |
|
Tiv tauj brazing |
Kub 780-820 ° C, huab cua, sib koom ua ke |
Txhua 100 units |
Thermocouple, shear tester |
|
Lub tsev molding |
Kub 280-320 ° C, siab, qhov ntev |
Txhua lub voj voog |
SCADA saib xyuas, SPC kab kos |
|
Mechanism sib dhos |
Toggle quab yuam, kev sib cuag, DIN clip force |
Txhua chav |
Force gauge, automated test bench |
|
Cov khoom kuaj |
Txuj |
Qauv Loj |
|
Pickup / tso tawm voltage |
0.85-1.1 × Peb khaws, > 0.2 × Peb tso tawm |
100% |
|
Coil zog siv |
Tsis pub dhau ± 10% ntawm qhov ntsuas (AC / DC hom) |
100% |
|
Tiv tauj tiv thaiv |
<5mΩ rau tus ncej |
100% |
|
Dielectric tiv taus voltage |
2 kV AC / 1 min |
100% |
|
Rwb thaiv tsev tsis kam |
> 100MΩ @ 500V DC |
100% |
|
Mechanical ua haujlwm |
10 ON-OFF cycles, du, tsis muaj nplaum |
100% |
|
DIN rail mounting quab yuam |
Snap-on 50-100N, tshem tawm 30-80N |
100% |
|
Visual & Dimension soj ntsuam |
17.5mm modularity, cim kev ruaj khov |
100% |
|
EMC kev tiv thaiv (electronic coils) |
ESD, tawg, nce kev tiv thaiv |
AQL 1.0 |
|
Ntim kev ncaj ncees |
Poob xeem, kev vibration (ISTA 3A) |
Rau ntau |
|
Qeb khoom siv |
Tshuab Specification |
Muaj nuj nqi |
Muaj peev xwm |
|
High-Speed Stamping |
100-ton progressive tuag xovxwm |
Laminated core stamping, hu rau tus neeg nqa khoom sib sau |
3 lab stampings / hnub |
|
Automated Winding |
CNC coil winding tshuab |
Coil ntau lawm nrog precision txheej |
15,000 coils / hnub |
|
Nqus impregnation |
VPI system nrog polyester / epoxy cob |
Coil void tshem tawm, rwb thaiv tsev txhim khu kev qha |
5,000 coils / batch |
|
Thermoplastic Moulding |
80-tuj txhaj tshuaj |
Modular vaj tsev ntau lawm (17.5mm suab) |
8,000 tsev/hnub |
|
AC / DC Module Sib dhos |
SMT kab nrog AOI, ICT, kev xeem ua haujlwm |
Electronic coil module ntau lawm |
10,000 modules / hnub |
|
Kev sib dhos |
Sau cov kab sib dhos |
Mechanism sib dhos, calibration, kuaj |
5,000 units / hnub ib kab |
|
Cov khoom siv kuaj |
Automated contactor kuaj lub rooj ntev zaum |
Pickup/dropout, sij hawm, endurance |
1,000 units / teev |
|
Mechanical endurance tester |
100,000 lub voj voog pov thawj |
200 units ib txhij |
|
|
EMC chav kuaj |
Kev tiv thaiv kab mob rau cov kab hluav taws xob |
100 units / hnub |
|
Yam khoom |
Muaj peev xwm txhua hli |
Standard Lead Time |
Ceev Order Muaj peev xwm |
|
Txheem AC coil (16A-25A, 2NO) |
100,000 units |
4-5 lub lis piam |
3 hnub |
|
AC / DC universal kauj (16A-40A) |
80,000 units |
4-5 lub lis piam |
5 hnub |
|
4-Pole contactors (25A-63A) |
60,000 units |
4-5 lub lis piam |
7 noj |
|
High tam sim no (80A-100A) |
50,000 units |
4-5 lub lis piam |
10 hnub |
|
Electronic coil nrog kev sib txuas lus |
50,000 units |
4-5 lub lis piam |
7 noj |
|
Department |
Cov neeg ua haujlwm |
Kev txawj ntse |
Lub luag haujlwm |
|
R & D Engineering |
5 cov engineers |
Lub tsev automation, ntsiag to AC / DC thev naus laus zis, kev sib koom ua ke ntawm daim phiaj ntse, cov ntaub ntawv tshawb fawb |
Kev tsim khoom tshiab, IoT-enabled contactors, patent portfolio (30+ patents) |
|
Txheej Txheem Engineering |
15 engineers |
Precision stamping, coil winding, thermoplastic molding, lean manufacturing |
Ntau lawm optimization, automation, yield txhim kho (> 99%) |
|
Kev xeem & validation |
12 engineers |
IEC 61095 (TSI) (TSI) Kev ua raws cai, EMC kuaj, ib puag ncig simulation, kev ntseeg siab engineering |
Hom kev soj ntsuam kev sib koom tes, tsis ua hauj lwm tsom xam, kev tswj xyuas ntawv pov thawj |
|
Application Engineering |
8 cov engineers |
Lub tsev tsim hluav taws xob tsim, tswj teeb pom kev zoo, HVAC systems, kev tswj hluav taws xob |
Cov neeg siv khoom txhawb nqa, kev tsim qauv, commissioning |
|
Quality Assurance |
25 tus kws tshaj lij |
ISO 9001, ISO 14001, statistical process control, metrology laboratory |
Supplier audit, txheej txheem audit, kho kom raug |
|
Daim ntawv pov thawj |
Muab Lub Cev |
Scope |
Kev siv tau |
|
ISO 9001: 2015 |
ZHONGDA HUAYUAN |
Kev tswj hwm zoo |
Kev soj ntsuam txhua xyoo |
|
IEC 61095 (TSI) (TSI): 2023 Hom Kev Xeem |
VDE |
Kev ua haujlwm hauv tsev contactor |
Ib yam khoom series |
|
CE Marking |
Ceeb Toom Lub Cev |
EU kev lag luam nkag |
Tsim-dependent |
|
VDE Certification |
VDE Test Institute |
German zoo daim ntawv lo |
Ib yam khoom series |
|
CCC (Tuam Tshoj) |
CQC |
Suav daim ntawv pov thawj |
5-xyoo lav |
|
CB Scheme |
IECEE |
International ntawv pov thawj |
Ib yam khoom series |
Peb qhov chaw tsim khoom sawv cev rau 15 xyoo ntawm kev tshwj xeeb hauv kev tsim cov automation contactors, xa cov neeg tiv tauj modular uas tshaj cov qauv thoob ntiaj teb los ntawm:
Silent technology kev coj noj coj ua: Proprietary AC / DC universal coil tsim nrog kev hloov hluav taws xob, ua tiav kev ua haujlwm <30dB-zoo tagnrho rau lub suab nrov-rhiab qhov chaw nyob thiab tos txais qhua
Vertical kev koom ua ke: Hauv tsev laminated core stamping, coil winding nrog lub tshuab nqus tsev impregnation, thiab thermoplastic vaj tsev molding kom ua tiav kev tswj xyuas zoo thiab kev hloov kho sai
Ua raws li IEC 61095: 2023: Kev saws me nyuam thaum ntxov ntawm tus qauv tshiab suav nrog AC-7d LED teeb pom kev zoo, txhim kho EMC kev tiv thaiv, thiab hloov kho cov ntawv cim npe
Kev ntsuam xyuas infrastructure: $ 2M + nqis peev rau hauv kev sim ntsuas suav nrog 100,000-lub voj voog kev ntsuas kev ntsuas hluav taws xob, EMC kev ntsuas kev tiv thaiv, thiab ib puag ncig simulation
Lub tsev ntse npaj txhij: IoT-enabled contactors nrog lub zog ntsuas, tswj chaw taws teeb, thiab BACnet / Modbus kev koom ua ke rau kev tswj hwm lub tsev niaj hnub