Cov khoom

Tuam Tshoj Durable MCB Accessories Supplier

CDADAyog cov chaw tsim khoom thiab cov chaw muag khoom ntawm ntau yam khoom siv hluav taws xob qis thiab lwm yam khoom siv, suav nrog MCB accessories. Peb 52,400 m² qhov chaw ua haujlwm ua lub hauv paus tsim khoom uas ua rau peb muab cov khoom lag luam wholesale, thiab peb kuj txais tos OEM customization thov. Thov koj xav tiv tauj peb rau kev hais lus.

 

MCB Accessories yog dab tsi?

MCB accessories yog cov khoom siv ntxiv tsim los txhim kho kev ua haujlwm, kev tiv thaiv, thiab kev tswj cov peev txheej ntawmMiniature Circuit Breakers (MCBs). Cov modular add-ons no hloov cov cuab yeej tiv thaiv hluav taws xob rau hauv cov khoom ntse, kev sib koom ua ke ntawm cov tshuab hluav taws xob niaj hnub. Ua haujlwm hauv qabIEC 60898-1 Cov (circuit-breakers rau tsev neeg thiab zoo sib xws installation) thiabIEC 60947-5-1 Cov (tswj cov khoom siv hluav taws xob), MCB cov khoom siv ua haujlwm ua haujlwm rau cov chaw taws teeb, saib xyuas cov xwm txheej, kev cuam tshuam kev nyab xeeb, thiab kev sib txuas tsis sib haum nrog kev tswj hwm lub tsev.

MCB accessories yog characterized los ntawm lawvmodular 17.5mm dav (ib nrab-module los yog tag nrho-module tsim), tso cai rau lawv mount ncaj qha rau ntawm DIN rails nrog MCBs los yog clip mus rau lub breaker lub cev. Cov qauv qauv no ua kom muaj kev sib raug zoo thoob plaws cov tuam txhab loj xws li Schneider Electric, ABB, Hager, Siemens, thiab Chint.

Kev lag luam thoob ntiaj teb MCB tau ntsib kev loj hlob tseem ceeb los ntawm kev siv lub tsev ntse, kev tswj hwm lub zog, thiab kev lag luam automation, nrog cov tuam txhab muab cov ntaub ntawv nthuav dav uas txhim kho kev nyab xeeb, yooj yim, thiab kev txawj ntse.

 

MCB Accessory Product Categories & Configurations

Qeb

Yam khoom siv

Muaj nuj nqi

Technical Specifications

Kev ua haujlwm nyob deb

Shunt Trip (ST)

Tej thaj chaw deb tripping ntawm sab nraud voltage teeb liab

AC: 24V, 110V, 230V, 415V; DC: 12V, 24V, 48V, 110V; Inrush 200VA (AC) / 200W (DC), kaw 20VA (AC) / 20W (DC); Lub sij hawm mus ncig <50ms; Dav: 17.5mm (1 module) 

Undervoltage Release (UVR)

Tsis siv neeg tripping thaum voltage poob qis dua qhov pib

Pickup: 0.85 × Un; Kev poob qis: 0.35-0.7 × Un (35-70% ntawm qhov ntsuas); Tiv thaiv tsis siv neeg rov kaw; Dav: 17.5mm (1 module) 

Overvoltage tso tawm

Kev mus ncig thaum qhov hluav taws xob muaj kev nyab xeeb tshaj qhov txwv

Feem ntau 270-280V AC rau 230V systems; Tiv thaiv cov xwm txheej overvoltage 

Lub cev muaj zog ua haujlwm ntaus ntawv

Kev them nyiaj hluav taws xob thiab chaw taws teeb ON / OFF ua haujlwm

230V AC mov, 3-5s lub sijhawm ua haujlwm, phau ntawv hla dhau, txoj haujlwm tawm tswv yim 

Status Signaling

Kev Pabcuam Tiv Thaiv (AX)

Qhia txog txoj haujlwm breaker (ON/OFF)

1NO + 1NC lossis 2NO + 2NC, 6A ntawm 230V AC / 3A ntawm 400V AC, nyiaj alloy hu; Dav: 9mm (0.5 module) 

Tswb Contact (AL)

Cov teeb liab breaker tripped vim yog txhaum

1NO + 1NC, ua haujlwm nkaus xwb ntawm kev mus ncig tsis siv neeg (tsis yog phau ntawv OFF), txawv ntawm pab pawg; Dav: 9mm (0.5 module) 

Fault Signal Contact

Qhia txog tej yam txhaum

Microswitch-based, kev koom ua ke nrog cov khoom siv hluav taws xob mus ncig

Kev Nyab Xeeb & Kev Ruaj Ntseg

Padlock Attachment

Locks breaker hauv ON lossis OFF txoj haujlwm

Txais 2 padlocks nrog 4.75mm hasps; Tiv thaiv kev ua haujlwm tsis raug cai 

Cov khoom siv xauv

Ruaj ntseg toggle nyob rau hauv ib txoj hauj lwm

Rau kev saib xyuas kev kaw haujlwm / tagout (LOTO) cov txheej txheem 

Busbar Systems

Pin-type Busbar

1-theem lossis 3-theem muab kev sib txuas

1m ntev, mus txog 56 tus ncej, 100A ntsuas, insulated 

Fork-type Busbar

Multi-pole faib

Rau 1P, 2P, 3P, 4P configurations, lateral connectors muaj 

Kev Tiv Thaiv & Kev Qhia

Terminal Cov

Tiv thaiv kev sib cuag

IP20 rau IP40, theem teeb meem, tus ntiv tes ruaj ntseg tsim

Cov Cim Cim

Kev txheeb xyuas Circuit Court

13-module strips rau labeling, snap-on installation 

Smart/Kev sib txuas lus

Wireless Auxiliary

Bluetooth/WiFi saib xyuas xwm txheej

Tuya App tau tshaj, tus kheej-powered los yog roj teeb, ceeb toom real-time 

 

Accessory Combination Txoj Cai:

Kev sib xyaw ua ke siab kawg: 3 add-on blocks ib MCB (feem ntau sab laug nkaus xwb)

Qhov chaw: 1 undervoltage lossis shunt tso ncaj qha rau ntawm MCB sab, tom qab ntawd 2 hu ( pabcuam + tswb)

Dav qauv: 9mm (0.5 module) rau kev sib cuag, 17.5mm (1 module) rau kev tshaj tawm

 

Core Functions & Txoj Cai Ua Haujlwm

Shunt Trip (ST) - Tej thaj chaw deb Tripping Mechanism

Cheebtsam

Muaj nuj nqi

Cov ntsiab lus technical

Electromagnetic Chev

Tsim magnetic teb thaum muaj zog

AC: Inrush 200VA, kaw 20VA; DC: Inrush 200W, kaw 20W; Rwb thaiv tsev chav F (155 ° C) lossis H (180 ° C)

Plunger Mechanism

Strikes mus txawv tebchaws bar kom tso mechanism

Hardened steel, caij nplooj ntoos hlav-rov qab, stroke 3-5mm, quab yuam 2-5N

Mounting

Snap-fit ​​ntawm MCB sab laug

Cov cuab yeej-dawb installation, tsis siv neeg sib dhos nrog kev mus ncig bar

Qhov taw qhia

Mechanical chij ntawm fascia

Visual indication ntawm coil ua haujlwm 

Kev khiav hauj lwm ib ntus:

Tswj voltage siv rau shunt mus txawv tebchaws terminals (A1-A2)

Coil energizes, generating magnetic teb (AC lossis DC)

Plunger ntaus MCB mus ncig ua si bar nrog lub zog txaus los kov yeej lub tshuab latch

MCB kev mus ncig qhib, kev sib cuag tseem ceeb sib cais

Mechanical chij qhia txog kev ua haujlwm ntawm shunt

Coil de-energizes, plunger rov qab los ntawm lub caij nplooj ntoos hlav

MCB xav kom rov pib dua phau ntawv (rov qhib dua)

 

Daim ntawv thov:

Emergency stop systems (E-stop nyees khawm)

Hluav taws kub tswb system kev koom ua ke (automatic shutdown)

Tej thaj chaw deb load shedding (xav tau cov kev pab cuam teb)

Generator hloov schemes (synchronized qhib)

 

Undervoltage Release (UVR) - Kev ntsuas hluav taws xob

Parameter

Specification

Kev nyab xeeb muaj nuj nqi

Txais Voltage

0.85 × Un (tuaj yeem kaw tau)

Tiv thaiv kev kaw ntawm qhov hluav taws xob tsis txaus

Tshem tawm Voltage

0.35-0.70 × Un (35-70% ntawm qhov ntsuas)

Tsis siv neeg mus ncig ntawm undervoltage

Sijhawm ncua

Instantaneous lossis 0.1-3s (hom hluav taws xob)

Tiv thaiv kev ntxhov siab los ntawm kev poob qis

Lub luag haujlwm txuas ntxiv

100% ntsuas voltage

Coil energized tsis tu ncua thaum lub sijhawm ua haujlwm

Dav

17.5mm (1 module)

Txheem DIN rail mounting 

 

Txoj Cai Kev Ua Haujlwm: UVR coil tseem ua haujlwm tsis tu ncua thaum lub sijhawm ua haujlwm ib txwm muaj, txhua yam tuav lub MCB kaw tshuab. Thaum cov khoom siv hluav taws xob poob qis hauv qab qhov kev tso tawm rau lub sijhawm teev tseg:

Electromagnetic quab yuam ua tsis txaus los tuav lub latch

Mechanical caij nplooj ntoos hlav tsav mus ncig teb chaws mechanism

MCB qhib tau txais

Tiv thaiv kom rov qab kaw kom txog thaum qhov hluav taws xob rov qab mus rau qib nqa

 

Qhov no tiv thaiv:

Motors los ntawm qis-voltage pib (siab tam sim no, overheating)

Cov khoom siv los ntawm kev puas tsuaj brownout

Kev nyab xeeb tiv thaiv tsis tau rov pib dua tom qab lub zog rov qab los

 

Pab vs. Tswb Contacts

Feature

Kev Pabcuam Tiv Thaiv (AX)

Tswb Contact (AL)

Kev ua haujlwm

Hloov lub xeev nrog MCB tuav txoj hauj lwm

Ua haujlwm tsuas yog ntawm kev mus ncig tsis siv neeg (overload / luv-circuit)

Qhov taw qhia

ON/OFF xwm txheej

Ua txhaum kev mus ncig nkaus xwb

Hu rau Configuration

1NO + 1NC lossis 2NO + 2NC

1NO + 1NC tus qauv

Kev ntsuas

6A ntawm 230V AC, 3A ntawm 400V AC

6A ntawm 230V AC, 3A ntawm 400V AC

Dav

9mm (0.5 module)

9mm (0.5 module)

Daim ntawv thov

Cov xwm txheej qhia, sib cuam tshuam, tswj circuits

Fault alarm, ceeb toom txij nkawm, qhia txog kev mus ncig 

 

Daim Ntawv Thov Ib puag ncig & Siv Case

Daim ntawv thov

Accessory Configuration

Kev Xav Tau

Kev koom ua ke

Cov Tsev Nyob Hauv Tsev Smart

Shunt mus txawv tebchaws + Pab + Wireless module

230V AC, WiFi / Bluetooth, Tuya App

Tsev automation, chaw taws teeb tswj, kev tswj fais fab

Cov tsev lag luam

UVR + Auxiliary + Tswb

230V AC, BMS kev koom ua ke, hluav taws kub tswb interface

Lub Tsev Tswj Xyuas Qhov System, kaw thaum muaj xwm ceev

Kev Tswj Lag Luam

Shunt mus txawv tebchaws + 2 × Pabcuam + Lub cev muaj zog

24V DC, PLC compatibility, teb ceev (<50ms)

PLC / DCS tswj, tshuab kev nyab xeeb circuits

Cov Tsev Kho Mob

UVR + Tswb + Padlock

Kev kho mob-qib, kev ntseeg siab, LOTO muaj peev xwm

Kev tswj fais fab tseem ceeb, kev tswj xyuas kev nyab xeeb

Data Centers

Shunt mus txawv tebchaws + Tswb + Busbar system

48V DC, siab ceev, modular expansion

Fais fab faib units (PDUs), tswj chaw taws teeb

Lub zog tauj dua tshiab

Shunt mus txawv tebchaws + Overvoltage tso tawm

1000V DC systems, kev ntsuam xyuas sab nraum zoov, kaw nrawm

Hnub ci PV systems, lub zog cia, inverter kev koom ua ke

Roj & Roj

Cov khoom siv tawg-pov thawj + UVR

ATEX / IECEx tau ntawv pov thawj, tropicalized

Kev kaw thaum muaj xwm txheej ceev (ESD), thaj chaw muaj kev phom sij

Infrastructure

Tus neeg tsav tsheb lub cev muaj zog + Pab txhawb nqa + Lub xauv qhov tseem ceeb

400V AC, hnyav-duty, 50,000 lub neej voj voog

SCADA systems, chaw taws teeb tswj chaw taws teeb 

 

Kev tsim khoom & Kev ua haujlwm ntau lawm

Precision Manufacturing Sequence

Raw Khoom IQC → Electromagnetic Chev Winding → Plunger / Armature Machining → Sib cuag System Fabrication → Tsev Txhaj Molding → Sub-Assembly → Calibration & Test → Final Integration → Ntim


Cov theem tsim khoom tseem ceeb

Theem

Txheej txheem txheej txheem

Cov ntsiab lus tswj tau zoo

Coil Winding

Enameled tooj liab hlau (0.1-0.3mm), automated winding nrog nro tswj, lub tshuab nqus tsev vacuum impregnation

Hloov suav ± 1%, DC tsis kam ± 5%, dielectric zog 2kV / 1min, rwb thaiv tsev tsis kam> 100MΩ

Plunger Machining

Cold-dov hlau SPCC los yog hlau hmoov metallurgy, precision sib tsoo, hardening (HRC 45-55)

Dimensional kam rau ua ± 0.02mm, nto tiav Ra ​​0.8, sib nqus permeability> 5000

Hu rau Fabrication

Nyiaj-nickel (AgNi 90/10) stamping, riveting rau tooj liab nqa, so geometry sib sau

Hardness HV 80-120, tiv taus <50mΩ, brazing zog> 50MPa

Tsev Moulding

PA66 GF30 los yog PBT GF30, 280-320 ° C txhaj, 17.5mm modularity tseem ceeb

Dimensional kam rau ua ± 0.05mm, nrhiav qhov ntsuas> 600V, UL 94 V-0, kub tsis kam 160 ° C

Caij nplooj ntoos hlav Manufacturing

Roj-tempered carbon steel SWOSC-V lossis stainless hlau 301, CNC coiling, kev kho cua sov

Lub neej qaug zog> 100,000 cycles, caij nplooj ntoos hlav tus nqi ± 10%, so <5%

Sub-Assembly

Coil-plunger-hu rau kev sib koom ua ke, kev kho mob stroke, snap-fit ​​mechanism kuaj

Kev khiav hauj lwm voltage 0.85-1.1 × Un, mus ncig teb chaws quab yuam 2-5N, teb lub sij hawm <50ms

Calibration kawg

Pickup/dropout voltage verification (UVR), kev ntsuas lub sij hawm ua hauj lwm (shunt mus txawv tebchaws), tiv tauj kuj

100% automated test, data logging, traceability QR coding

 

Primary Raw Materials & Component Specifications

Cheebtsam

Khoom Specification

Tus qauv tsim khoom

Cov khoom tseem ceeb

Coil Hlau

Enameled tooj liab hlau Class F (155 ° C) los yog Class H (180 ° C)

IEC 60317, NEMA MW 35

Kev tawg voltage> 2kV, solderability 390 ° C / 2s, yooj

Sib nqus Core

Silicon steel laminations (0.35-0.5mm) los yog hlau khoom

IEC 60404-8, JIS C 2552

High permeability, tsis tshua muaj coercivity, zoo ib yam magnetic zog

Plunger/Armature

Cold-dov hlau SPCC lossis hlau hmoov (Fe-99%)

JIS G 3141, MPIF Standard 35

HRC 45-55, nto tiav Ra ​​0.8, corrosion kuj

Tiv tauj

Silver-nickel (AgNi 90/10) los yog silver-cadmium oxide (AgCdO)

ASTM B152, IEC 60368, Kev Tswj Xyuas Zoo

Conductivity> 90% IACS, arc yaig tsis kam, tiv thaiv vuam

Hu rau Springs

Beryllium tooj liab (CuBe2 C17200) los yog stainless hlau 301

ASTM B196

Kev qaug zog lub neej> 100,000 cycles, siab zoo, corrosion kuj

Tsev

PA66 GF30 (30% iav fiber) los yog PBT GF30

IEC 60664-1, UL 94 V-0

Kev ntsuas ntsuas> 600V, kub tsis kam 160 ° C, cuam tshuam lub zog> 7 kJ / m²

DIN Rail Clip

Lub caij nplooj ntoos hlav steel 65Mn lossis stainless hlau 304, zinc-plated

GB/T 1222, ISO 3506

Clamp quab yuam 50-100N, 10,000 lub voj voog qaug zog, corrosion kuj

Terminals

Brass C36000 los yog tooj liab C11000 nrog tin plating (5-8μm)

ASTM B16 / B187 Kev ntsuas

Tam sim no ceev 1.0-1.5 A / mm², torque withstand 1.5-2.5Nm

 

Standards Compliance & Testing Protocols

International Standards Framework

Txuj

Scope

Cov Kev Xav Tau

IEC 60898-1 Cov Cov

Circuit Court-breakers rau tsev neeg thiab zoo sib xws installation

Lub hauv paus txheem rau MCBs, accessory compatibility

IEC 60947-5-1 Cov Cov

Tswj cov khoom siv hluav taws xob thiab hloov cov khoom siv

Kev pabcuam kev sib cuag, hluav taws xob endurance, cov cim davhlau ya nyob twg

IEC 60947-2: Cov

Tsawg-voltage switchgear - Circuit Court breakers

Shunt mus txawv tebchaws / UVR kev ua haujlwm, kev sib koom tes

EN 60898-1 / EN 60947-5-1

European kev sib haum xeeb versions

CE cim, EU kev lag luam nkag

 

Yam yuav tsum tau ua (IEC 60947-5-1 / IEC 60898)

Qeb xeem

Kev Xeem Tshwj Xeeb

Kev lees txais

Hluav taws xob Endurance

10,000 kev ua haujlwm ntawm qhov ntsuas tam sim no (AC-15 / DC-13)

Tiv tauj hnav <50%, tsis muaj vuam, ua haujlwm zoo ib yam

Mechanical Endurance

100,000 tsis-load haujlwm

<5% parameter drift, tsis muaj txhua yam tsis ua haujlwm

Dielectric Properties

2kV AC / 1min (tswj circuits), 4kV impulse

Tsis muaj kev tawg, tsis muaj flashover

Kub nce

Kev ua haujlwm tsis tu ncua ntawm qhov ntsuas voltage / tam sim no

Chev ≤85K (Class F), terminals ≤80K

Shock & Vibration

IEC 60068-2-27 (kev poob siab), IEC 60068-2-6 (kev vibration)

Tsis muaj kev ua haujlwm tsis raug, tsis muaj kev puas tsuaj, ua haujlwm tom qab kuaj

Ib puag ncig

Kev kub ceev (IEC 60068-2-30), txias, qhuav cua sov

Ua haujlwm tom qab txias, tsis muaj corrosion

EMC

Kev tiv thaiv rau kev cuam tshuam / radiated cuam tshuam

TS EN 60947-5-1: Tsis muaj kev cuam tshuam

 

Factory Quality Control & Inspection Standards

Cov khoom xa tuaj QC (IQC)

Khoom siv

Cov khoom soj ntsuam

Sampling Plan

Khoom siv

Enameled hlau

Txoj kab uas hla, tawg voltage, elongation, solderability

TSI 0.65

Micrometer, dielectric tester, tensile tshuab

Sib nqus hlau

Permeability, core poob, rwb thaiv tsev txheej

Rau batch

Epstein ncej, ib daim ntawv tester

Nyiaj tiv tauj

Purity, hardness, ntom, dimensional kam rau ua

Rau batch

Spectrometer, hardness tester, CMM

Yas granules

Cov ntsiab lus iav, viscosity, noo noo, flammability

Rau batch

Melt flow indexer, DSC, UL 94 apparatus

Caij nplooj ntoos hlav steel

Tensile zog, qaug zog kuj, sib sau

Rau batch

Tensile tshuab, qaug zog tester

 

In-Process Quality Control (IPQC)

Chaw nres tsheb

Tswj Parameters

Ntau zaus

Txoj kev

Coil winding

Hloov suav, nro, tsis kam, rwb thaiv tsev

Txhua chav

Automated winding nrog tawm tswv yim, ohmmeter

Plunger machining

Dimensional kam rau ua, nto tiav, hardness

Txhua 100 units

CMM, profileometer, hardness tester

Hu rau kev sib dhos

Alignment, siab, tsis kam, brazing zoo

Txhua 100 units

Lub zog ntsuas, micro-ohmmeter, XRF

Lub tsev molding

Kub, siab, qhov tseeb

Txhua lub voj voog

SCADA saib xyuas, SPC kab kos

Sub-assembly

Kev khiav hauj lwm voltage, stroke, teb lub sij hawm

Txhua chav

Automated xeem lub rooj ntev zaum, cov ntaub ntawv logging

 

Kev Tswj Xyuas Qhov Kawg (FQC) & QC (OQC)

Cov khoom kuaj

Txuj

Qauv Loj

Kev khiav hauj lwm voltage

0.85-1.1 × Un (pickup), > 0.2 × Un (dropout rau UVR)

100%

Lub sijhawm teb (shunt trip)

<50ms ntawm qhov ntsuas hluav taws xob

100%

Tiv tauj tiv thaiv

<50mΩ (ntsuas), <100mΩ ( tswb)

100%

Dielectric tiv taus voltage

2 kV AC / 1 min

100%

Rwb thaiv tsev tsis kam

> 100MΩ @ 500V DC

100%

Mechanical ua haujlwm

10 cycles, du, tsis sticking

100%

Snap-fit ​​compatibility

Mating nrog tsim MCB ncej

100%

Visual & Dimension soj ntsuam

17.5mm modularity, cim kev ruaj khov

100%

Hluav taws xob endurance sampling

1,000 kev ua haujlwm ntawm kev ntsuas load

AQL 1.0

Ntim kev ncaj ncees

Poob xeem, kev vibration (ISTA 3A)

Rau ntau

 

Kev Tsim Nyog Infrastructure & Manufacturing Capability

Cov cuab yeej tsim khoom siab heev

Qeb khoom siv

Tshuab Specification

Muaj nuj nqi

Muaj peev xwm

Coil Winding

CNC winding tshuab (Nittoku / Marsilli) nrog kev tswj nruj

Precision coil ntau lawm

20,000 coils / hnub

Stamping & Forming

60-ton progressive tuag xovxwm (Bruderer)

Hu rau stamping, caij nplooj ntoos hlav sib sau

30,000 Cheebtsam / hnub

Txhaj Molding

80-tuj thermoplastic xovxwm (Arburg)

Vaj tse, enclosures, DIN rail clips

10,000 tsev/hnub

Sib dhos Automation

Robotic cells (ABB/Fanuc) nrog rau lub zeem muag

Sub-assembly, calibration, kuaj

5,000 accessories / hnub ib kab

Cov khoom siv kuaj

Automated accessory xeem lub rooj ntev zaum

Cov yam ntxwv ua haujlwm, lub sijhawm, kev ua siab ntev

1,000 units / teev

Mechanical endurance tester

100,000 lub voj voog pov thawj

200 units ib txhij

EMC chav kuaj

Kev ntsuas kev tiv thaiv / emission

100 units / hnub

 

Muaj Peev Xwm Ntau Lawm & Lub Sijhawm Lead

Yam khoom

Muaj peev xwm txhua hli

Standard Lead Time

Ceev Order Muaj peev xwm

Shunt Trips (tag nrho cov voltages)

50,000 units

4-5 lub lis piam

3 hnub

Undervoltage tso tawm

20,000 units

4-5 lub lis piam

3 hnub

Kev Sib Txuas Sib Txuas

10,000 units

4-5 lub lis piam

3 hnub

Tswb Contacts

50,000 units

4-5 lub lis piam

3 hnub

Lub cev muaj zog ua haujlwm Devices

50,000 units

4-5 lub lis piam

5 hnub

Busbar Systems

1,000 meters

4-5 lub lis piam

3 hnub

 

Engineering & Technical Team Structure

Department

Cov neeg ua haujlwm

Kev txawj ntse

Lub luag haujlwm

R & D Engineering

5

 engineers

Electromagnetic tsim, hu rau physics, IoT kev koom ua ke, kev sib txuas lus wireless

Kev txhim kho khoom siv tshiab, ntse nta, patent portfolio (30+ patents)

Txheej Txheem Engineering

15 engineers

Coil winding automation, precision stamping, yas molding, lean manufacturing

Kev tsim kho kom zoo, kev txhim kho cov txiaj ntsig (> 99%), txo nqi

Kev xeem & validation

12 engineers

IEC 60898 / 60947 Kev ua raws, kev sim siab, EMC, ib puag ncig simulation

Hom kev soj ntsuam kev sib koom tes, tsis ua hauj lwm tsom xam, kev tswj xyuas ntawv pov thawj

Application Engineering

10 engineers

MCB kev koom ua ke, tswj tshuab, BMS / SCADA interface

Cov neeg siv khoom txhawb nqa, kev tsim qauv, commissioning

Quality Assurance

25 tus kws tshaj lij

ISO 9001, IATF 16949, statistical process control, metrology

Supplier audit, txheej txheem audit, kho kom raug, calibration

 

Vim Li Cas Peb MCB Accessory Manufacturing Stands Sib nrug

Peb qhov chaw tsim khoom sawv cev20 xyoo kev tshwj xeeb nyob rau hauv qis-voltage Circuit Court tiv thaiv accessories, xa MCB accessories uas tshaj ntiaj teb no cov qauv los ntawm:

 

Modular kev txawj ntse: Kev nkag siab tob ntawm 17.5mm DIN rail modularity, ua kom muaj kev sib txuam nrog MCBs los ntawm cov tuam txhab loj (Schneider Acti9, ABB System pro M, Siemens Sentron, Hager)

Smart accessory innovation: Proprietary wireless auxiliary contacts thiab lub zog saib xyuas sensors uas hloov cov pa MCBs rau hauv IoT-enabled ntse li yam tsis muaj kev hloov pauv

Vertical kev koom ua ke: Nyob rau hauv tsev coil winding nrog lub tshuab nqus tsev impregnation, precision contact stamping, thiab thermoplastic molding kom ua tiav kev tswj xyuas zoo thiab kev hloov kho sai

Kev ntsuam xyuas infrastructure: $ 2M + nqis peev hauv automated test nrog rau 100,000-cycle mechanical endurance verification, EMC immunity testing, thiab MCB compatibility testing

Ceev ceev customization: Saj zawg zog manufacturing enabling voltage, tiv tauj configuration, thiab kev sib txuas lus raws tu qauv customization nrog 2-lub lim tiam ua lead lub sij hawm

 

View as  
 
MCB Shunt Tso Tawm

MCB Shunt Tso Tawm

Xaiv CDADA raws li koj tus MCB Shunt Release tsum, cov khoom no yog rau kev tswj chaw taws teeb ntawm koj DAB7-63 Circuit Court breakers. Muaj nyob rau hauv 24V txog 400V AC / DC, nws ua kom ntseeg tau kev ua haujlwm nyob rau hauv ntau qhov hluav taws xob ntau. Zoo tagnrho rau kev kaw thaum muaj xwm ceev thiab automation systems. Yooj yim rau nruab, nrog kev sib raug zoo ncaj qha rau CDADA's DAB7 series-tsis muaj qhov hloov pauv ntxiv.
MCB Tswb thiab Pab Pawg Sib Txuas

MCB Tswb thiab Pab Pawg Sib Txuas

Yuav CDADA MCB Tswb thiab Kev Sib Txuas Sib Txuas - dual-function module rau DAB7-63 breakers. Muab 2 tus neeg sib txuas lus sib txuas (auxiliary + tswb) nyob rau hauv ib chav tsev compact. Qhov zoo tshaj plaws rau kev saib xyuas tej thaj chaw deb thiab teeb meem txhaum cai hauv cov vaj huam sib luag. Yooj yim sab laug-sab snap-on nruab. Raws li lub Hoobkas ncaj qha, OEM / tus nqi muag khoom muaj.
CDADA yog MCB Accessories cov chaw tsim khoom thiab cov chaw muag khoom hauv Suav teb. Peb lub Hoobkas ua haujlwm rau ntau hom kev lag luam xws li lub tshuab hluav taws xob, lub tsev automation, thiab kev tsim khoom lag luam, muab cov kev daws teeb meem OEM / ODM hloov tau.
X
Peb siv cov ncuav qab zib los muab koj cov kev tshawb fawb zoo dua, txheeb xyuas qhov chaw khiav tsheb thiab kho cov ntsiab lus tus kheej. Los ntawm kev siv lub xaib no, koj pom zoo rau peb siv cov ncuav qab zib.Txoj Cai Tswjfwm Ntiag Tug
Tsis lees paubTxais