CDADAyog cov chaw tsim khoom thiab cov chaw muag khoom ntawm ntau yam khoom siv hluav taws xob qis thiab lwm yam khoom siv, suav nrog MCB accessories. Peb 52,400 m² qhov chaw ua haujlwm ua lub hauv paus tsim khoom uas ua rau peb muab cov khoom lag luam wholesale, thiab peb kuj txais tos OEM customization thov. Thov koj xav tiv tauj peb rau kev hais lus.
MCB accessories yog cov khoom siv ntxiv tsim los txhim kho kev ua haujlwm, kev tiv thaiv, thiab kev tswj cov peev txheej ntawmMiniature Circuit Breakers (MCBs). Cov modular add-ons no hloov cov cuab yeej tiv thaiv hluav taws xob rau hauv cov khoom ntse, kev sib koom ua ke ntawm cov tshuab hluav taws xob niaj hnub. Ua haujlwm hauv qabIEC 60898-1 Cov (circuit-breakers rau tsev neeg thiab zoo sib xws installation) thiabIEC 60947-5-1 Cov (tswj cov khoom siv hluav taws xob), MCB cov khoom siv ua haujlwm ua haujlwm rau cov chaw taws teeb, saib xyuas cov xwm txheej, kev cuam tshuam kev nyab xeeb, thiab kev sib txuas tsis sib haum nrog kev tswj hwm lub tsev.
MCB accessories yog characterized los ntawm lawvmodular 17.5mm dav (ib nrab-module los yog tag nrho-module tsim), tso cai rau lawv mount ncaj qha rau ntawm DIN rails nrog MCBs los yog clip mus rau lub breaker lub cev. Cov qauv qauv no ua kom muaj kev sib raug zoo thoob plaws cov tuam txhab loj xws li Schneider Electric, ABB, Hager, Siemens, thiab Chint.
Kev lag luam thoob ntiaj teb MCB tau ntsib kev loj hlob tseem ceeb los ntawm kev siv lub tsev ntse, kev tswj hwm lub zog, thiab kev lag luam automation, nrog cov tuam txhab muab cov ntaub ntawv nthuav dav uas txhim kho kev nyab xeeb, yooj yim, thiab kev txawj ntse.
|
Qeb |
Yam khoom siv |
Muaj nuj nqi |
Technical Specifications |
|
Kev ua haujlwm nyob deb |
Shunt Trip (ST) |
Tej thaj chaw deb tripping ntawm sab nraud voltage teeb liab |
AC: 24V, 110V, 230V, 415V; DC: 12V, 24V, 48V, 110V; Inrush 200VA (AC) / 200W (DC), kaw 20VA (AC) / 20W (DC); Lub sij hawm mus ncig <50ms; Dav: 17.5mm (1 module) |
|
Undervoltage Release (UVR) |
Tsis siv neeg tripping thaum voltage poob qis dua qhov pib |
Pickup: 0.85 × Un; Kev poob qis: 0.35-0.7 × Un (35-70% ntawm qhov ntsuas); Tiv thaiv tsis siv neeg rov kaw; Dav: 17.5mm (1 module) |
|
|
Overvoltage tso tawm |
Kev mus ncig thaum qhov hluav taws xob muaj kev nyab xeeb tshaj qhov txwv |
Feem ntau 270-280V AC rau 230V systems; Tiv thaiv cov xwm txheej overvoltage |
|
|
Lub cev muaj zog ua haujlwm ntaus ntawv |
Kev them nyiaj hluav taws xob thiab chaw taws teeb ON / OFF ua haujlwm |
230V AC mov, 3-5s lub sijhawm ua haujlwm, phau ntawv hla dhau, txoj haujlwm tawm tswv yim |
|
|
Status Signaling |
Kev Pabcuam Tiv Thaiv (AX) |
Qhia txog txoj haujlwm breaker (ON/OFF) |
1NO + 1NC lossis 2NO + 2NC, 6A ntawm 230V AC / 3A ntawm 400V AC, nyiaj alloy hu; Dav: 9mm (0.5 module) |
|
Tswb Contact (AL) |
Cov teeb liab breaker tripped vim yog txhaum |
1NO + 1NC, ua haujlwm nkaus xwb ntawm kev mus ncig tsis siv neeg (tsis yog phau ntawv OFF), txawv ntawm pab pawg; Dav: 9mm (0.5 module) |
|
|
Fault Signal Contact |
Qhia txog tej yam txhaum |
Microswitch-based, kev koom ua ke nrog cov khoom siv hluav taws xob mus ncig |
|
|
Kev Nyab Xeeb & Kev Ruaj Ntseg |
Padlock Attachment |
Locks breaker hauv ON lossis OFF txoj haujlwm |
Txais 2 padlocks nrog 4.75mm hasps; Tiv thaiv kev ua haujlwm tsis raug cai |
|
Cov khoom siv xauv |
Ruaj ntseg toggle nyob rau hauv ib txoj hauj lwm |
Rau kev saib xyuas kev kaw haujlwm / tagout (LOTO) cov txheej txheem |
|
|
Busbar Systems |
Pin-type Busbar |
1-theem lossis 3-theem muab kev sib txuas |
1m ntev, mus txog 56 tus ncej, 100A ntsuas, insulated |
|
Fork-type Busbar |
Multi-pole faib |
Rau 1P, 2P, 3P, 4P configurations, lateral connectors muaj |
|
|
Kev Tiv Thaiv & Kev Qhia |
Terminal Cov |
Tiv thaiv kev sib cuag |
IP20 rau IP40, theem teeb meem, tus ntiv tes ruaj ntseg tsim |
|
Cov Cim Cim |
Kev txheeb xyuas Circuit Court |
13-module strips rau labeling, snap-on installation |
|
|
Smart/Kev sib txuas lus |
Wireless Auxiliary |
Bluetooth/WiFi saib xyuas xwm txheej |
Tuya App tau tshaj, tus kheej-powered los yog roj teeb, ceeb toom real-time |
Kev sib xyaw ua ke siab kawg: 3 add-on blocks ib MCB (feem ntau sab laug nkaus xwb)
Qhov chaw: 1 undervoltage lossis shunt tso ncaj qha rau ntawm MCB sab, tom qab ntawd 2 hu ( pabcuam + tswb)
Dav qauv: 9mm (0.5 module) rau kev sib cuag, 17.5mm (1 module) rau kev tshaj tawm
|
Cheebtsam |
Muaj nuj nqi |
Cov ntsiab lus technical |
|
Electromagnetic Chev |
Tsim magnetic teb thaum muaj zog |
AC: Inrush 200VA, kaw 20VA; DC: Inrush 200W, kaw 20W; Rwb thaiv tsev chav F (155 ° C) lossis H (180 ° C) |
|
Plunger Mechanism |
Strikes mus txawv tebchaws bar kom tso mechanism |
Hardened steel, caij nplooj ntoos hlav-rov qab, stroke 3-5mm, quab yuam 2-5N |
|
Mounting |
Snap-fit ntawm MCB sab laug |
Cov cuab yeej-dawb installation, tsis siv neeg sib dhos nrog kev mus ncig bar |
|
Qhov taw qhia |
Mechanical chij ntawm fascia |
Visual indication ntawm coil ua haujlwm |
Tswj voltage siv rau shunt mus txawv tebchaws terminals (A1-A2)
Coil energizes, generating magnetic teb (AC lossis DC)
Plunger ntaus MCB mus ncig ua si bar nrog lub zog txaus los kov yeej lub tshuab latch
MCB kev mus ncig qhib, kev sib cuag tseem ceeb sib cais
Mechanical chij qhia txog kev ua haujlwm ntawm shunt
Coil de-energizes, plunger rov qab los ntawm lub caij nplooj ntoos hlav
MCB xav kom rov pib dua phau ntawv (rov qhib dua)
Emergency stop systems (E-stop nyees khawm)
Hluav taws kub tswb system kev koom ua ke (automatic shutdown)
Tej thaj chaw deb load shedding (xav tau cov kev pab cuam teb)
Generator hloov schemes (synchronized qhib)
|
Parameter |
Specification |
Kev nyab xeeb muaj nuj nqi |
|
Txais Voltage |
0.85 × Un (tuaj yeem kaw tau) |
Tiv thaiv kev kaw ntawm qhov hluav taws xob tsis txaus |
|
Tshem tawm Voltage |
0.35-0.70 × Un (35-70% ntawm qhov ntsuas) |
Tsis siv neeg mus ncig ntawm undervoltage |
|
Sijhawm ncua |
Instantaneous lossis 0.1-3s (hom hluav taws xob) |
Tiv thaiv kev ntxhov siab los ntawm kev poob qis |
|
Lub luag haujlwm txuas ntxiv |
100% ntsuas voltage |
Coil energized tsis tu ncua thaum lub sijhawm ua haujlwm |
|
Dav |
17.5mm (1 module) |
Txheem DIN rail mounting |
Txoj Cai Kev Ua Haujlwm: UVR coil tseem ua haujlwm tsis tu ncua thaum lub sijhawm ua haujlwm ib txwm muaj, txhua yam tuav lub MCB kaw tshuab. Thaum cov khoom siv hluav taws xob poob qis hauv qab qhov kev tso tawm rau lub sijhawm teev tseg:
Electromagnetic quab yuam ua tsis txaus los tuav lub latch
Mechanical caij nplooj ntoos hlav tsav mus ncig teb chaws mechanism
MCB qhib tau txais
Tiv thaiv kom rov qab kaw kom txog thaum qhov hluav taws xob rov qab mus rau qib nqa
Qhov no tiv thaiv:
Motors los ntawm qis-voltage pib (siab tam sim no, overheating)
Cov khoom siv los ntawm kev puas tsuaj brownout
Kev nyab xeeb tiv thaiv tsis tau rov pib dua tom qab lub zog rov qab los
|
Feature |
Kev Pabcuam Tiv Thaiv (AX) |
Tswb Contact (AL) |
|
Kev ua haujlwm |
Hloov lub xeev nrog MCB tuav txoj hauj lwm |
Ua haujlwm tsuas yog ntawm kev mus ncig tsis siv neeg (overload / luv-circuit) |
|
Qhov taw qhia |
ON/OFF xwm txheej |
Ua txhaum kev mus ncig nkaus xwb |
|
Hu rau Configuration |
1NO + 1NC lossis 2NO + 2NC |
1NO + 1NC tus qauv |
|
Kev ntsuas |
6A ntawm 230V AC, 3A ntawm 400V AC |
6A ntawm 230V AC, 3A ntawm 400V AC |
|
Dav |
9mm (0.5 module) |
9mm (0.5 module) |
|
Daim ntawv thov |
Cov xwm txheej qhia, sib cuam tshuam, tswj circuits |
Fault alarm, ceeb toom txij nkawm, qhia txog kev mus ncig |
|
Daim ntawv thov |
Accessory Configuration |
Kev Xav Tau |
Kev koom ua ke |
|
Cov Tsev Nyob Hauv Tsev Smart |
Shunt mus txawv tebchaws + Pab + Wireless module |
230V AC, WiFi / Bluetooth, Tuya App |
Tsev automation, chaw taws teeb tswj, kev tswj fais fab |
|
Cov tsev lag luam |
UVR + Auxiliary + Tswb |
230V AC, BMS kev koom ua ke, hluav taws kub tswb interface |
Lub Tsev Tswj Xyuas Qhov System, kaw thaum muaj xwm ceev |
|
Kev Tswj Lag Luam |
Shunt mus txawv tebchaws + 2 × Pabcuam + Lub cev muaj zog |
24V DC, PLC compatibility, teb ceev (<50ms) |
PLC / DCS tswj, tshuab kev nyab xeeb circuits |
|
Cov Tsev Kho Mob |
UVR + Tswb + Padlock |
Kev kho mob-qib, kev ntseeg siab, LOTO muaj peev xwm |
Kev tswj fais fab tseem ceeb, kev tswj xyuas kev nyab xeeb |
|
Data Centers |
Shunt mus txawv tebchaws + Tswb + Busbar system |
48V DC, siab ceev, modular expansion |
Fais fab faib units (PDUs), tswj chaw taws teeb |
|
Lub zog tauj dua tshiab |
Shunt mus txawv tebchaws + Overvoltage tso tawm |
1000V DC systems, kev ntsuam xyuas sab nraum zoov, kaw nrawm |
Hnub ci PV systems, lub zog cia, inverter kev koom ua ke |
|
Roj & Roj |
Cov khoom siv tawg-pov thawj + UVR |
ATEX / IECEx tau ntawv pov thawj, tropicalized |
Kev kaw thaum muaj xwm txheej ceev (ESD), thaj chaw muaj kev phom sij |
|
Infrastructure |
Tus neeg tsav tsheb lub cev muaj zog + Pab txhawb nqa + Lub xauv qhov tseem ceeb |
400V AC, hnyav-duty, 50,000 lub neej voj voog |
SCADA systems, chaw taws teeb tswj chaw taws teeb |
Raw Khoom IQC → Electromagnetic Chev Winding → Plunger / Armature Machining → Sib cuag System Fabrication → Tsev Txhaj Molding → Sub-Assembly → Calibration & Test → Final Integration → Ntim
|
Theem |
Txheej txheem txheej txheem |
Cov ntsiab lus tswj tau zoo |
|
Coil Winding |
Enameled tooj liab hlau (0.1-0.3mm), automated winding nrog nro tswj, lub tshuab nqus tsev vacuum impregnation |
Hloov suav ± 1%, DC tsis kam ± 5%, dielectric zog 2kV / 1min, rwb thaiv tsev tsis kam> 100MΩ |
|
Plunger Machining |
Cold-dov hlau SPCC los yog hlau hmoov metallurgy, precision sib tsoo, hardening (HRC 45-55) |
Dimensional kam rau ua ± 0.02mm, nto tiav Ra 0.8, sib nqus permeability> 5000 |
|
Hu rau Fabrication |
Nyiaj-nickel (AgNi 90/10) stamping, riveting rau tooj liab nqa, so geometry sib sau |
Hardness HV 80-120, tiv taus <50mΩ, brazing zog> 50MPa |
|
Tsev Moulding |
PA66 GF30 los yog PBT GF30, 280-320 ° C txhaj, 17.5mm modularity tseem ceeb |
Dimensional kam rau ua ± 0.05mm, nrhiav qhov ntsuas> 600V, UL 94 V-0, kub tsis kam 160 ° C |
|
Caij nplooj ntoos hlav Manufacturing |
Roj-tempered carbon steel SWOSC-V lossis stainless hlau 301, CNC coiling, kev kho cua sov |
Lub neej qaug zog> 100,000 cycles, caij nplooj ntoos hlav tus nqi ± 10%, so <5% |
|
Sub-Assembly |
Coil-plunger-hu rau kev sib koom ua ke, kev kho mob stroke, snap-fit mechanism kuaj |
Kev khiav hauj lwm voltage 0.85-1.1 × Un, mus ncig teb chaws quab yuam 2-5N, teb lub sij hawm <50ms |
|
Calibration kawg |
Pickup/dropout voltage verification (UVR), kev ntsuas lub sij hawm ua hauj lwm (shunt mus txawv tebchaws), tiv tauj kuj |
100% automated test, data logging, traceability QR coding |
|
Cheebtsam |
Khoom Specification |
Tus qauv tsim khoom |
Cov khoom tseem ceeb |
|
Coil Hlau |
Enameled tooj liab hlau Class F (155 ° C) los yog Class H (180 ° C) |
IEC 60317, NEMA MW 35 |
Kev tawg voltage> 2kV, solderability 390 ° C / 2s, yooj |
|
Sib nqus Core |
Silicon steel laminations (0.35-0.5mm) los yog hlau khoom |
IEC 60404-8, JIS C 2552 |
High permeability, tsis tshua muaj coercivity, zoo ib yam magnetic zog |
|
Plunger/Armature |
Cold-dov hlau SPCC lossis hlau hmoov (Fe-99%) |
JIS G 3141, MPIF Standard 35 |
HRC 45-55, nto tiav Ra 0.8, corrosion kuj |
|
Tiv tauj |
Silver-nickel (AgNi 90/10) los yog silver-cadmium oxide (AgCdO) |
ASTM B152, IEC 60368, Kev Tswj Xyuas Zoo |
Conductivity> 90% IACS, arc yaig tsis kam, tiv thaiv vuam |
|
Hu rau Springs |
Beryllium tooj liab (CuBe2 C17200) los yog stainless hlau 301 |
ASTM B196 |
Kev qaug zog lub neej> 100,000 cycles, siab zoo, corrosion kuj |
|
Tsev |
PA66 GF30 (30% iav fiber) los yog PBT GF30 |
IEC 60664-1, UL 94 V-0 |
Kev ntsuas ntsuas> 600V, kub tsis kam 160 ° C, cuam tshuam lub zog> 7 kJ / m² |
|
DIN Rail Clip |
Lub caij nplooj ntoos hlav steel 65Mn lossis stainless hlau 304, zinc-plated |
GB/T 1222, ISO 3506 |
Clamp quab yuam 50-100N, 10,000 lub voj voog qaug zog, corrosion kuj |
|
Terminals |
Brass C36000 los yog tooj liab C11000 nrog tin plating (5-8μm) |
ASTM B16 / B187 Kev ntsuas |
Tam sim no ceev 1.0-1.5 A / mm², torque withstand 1.5-2.5Nm |
|
Txuj |
Scope |
Cov Kev Xav Tau |
|
IEC 60898-1 Cov Cov |
Circuit Court-breakers rau tsev neeg thiab zoo sib xws installation |
Lub hauv paus txheem rau MCBs, accessory compatibility |
|
IEC 60947-5-1 Cov Cov |
Tswj cov khoom siv hluav taws xob thiab hloov cov khoom siv |
Kev pabcuam kev sib cuag, hluav taws xob endurance, cov cim davhlau ya nyob twg |
|
IEC 60947-2: Cov |
Tsawg-voltage switchgear - Circuit Court breakers |
Shunt mus txawv tebchaws / UVR kev ua haujlwm, kev sib koom tes |
|
EN 60898-1 / EN 60947-5-1 |
European kev sib haum xeeb versions |
CE cim, EU kev lag luam nkag |
|
Qeb xeem |
Kev Xeem Tshwj Xeeb |
Kev lees txais |
|
Hluav taws xob Endurance |
10,000 kev ua haujlwm ntawm qhov ntsuas tam sim no (AC-15 / DC-13) |
Tiv tauj hnav <50%, tsis muaj vuam, ua haujlwm zoo ib yam |
|
Mechanical Endurance |
100,000 tsis-load haujlwm |
<5% parameter drift, tsis muaj txhua yam tsis ua haujlwm |
|
Dielectric Properties |
2kV AC / 1min (tswj circuits), 4kV impulse |
Tsis muaj kev tawg, tsis muaj flashover |
|
Kub nce |
Kev ua haujlwm tsis tu ncua ntawm qhov ntsuas voltage / tam sim no |
Chev ≤85K (Class F), terminals ≤80K |
|
Shock & Vibration |
IEC 60068-2-27 (kev poob siab), IEC 60068-2-6 (kev vibration) |
Tsis muaj kev ua haujlwm tsis raug, tsis muaj kev puas tsuaj, ua haujlwm tom qab kuaj |
|
Ib puag ncig |
Kev kub ceev (IEC 60068-2-30), txias, qhuav cua sov |
Ua haujlwm tom qab txias, tsis muaj corrosion |
|
EMC |
Kev tiv thaiv rau kev cuam tshuam / radiated cuam tshuam |
TS EN 60947-5-1: Tsis muaj kev cuam tshuam |
|
Khoom siv |
Cov khoom soj ntsuam |
Sampling Plan |
Khoom siv |
|
Enameled hlau |
Txoj kab uas hla, tawg voltage, elongation, solderability |
TSI 0.65 |
Micrometer, dielectric tester, tensile tshuab |
|
Sib nqus hlau |
Permeability, core poob, rwb thaiv tsev txheej |
Rau batch |
Epstein ncej, ib daim ntawv tester |
|
Nyiaj tiv tauj |
Purity, hardness, ntom, dimensional kam rau ua |
Rau batch |
Spectrometer, hardness tester, CMM |
|
Yas granules |
Cov ntsiab lus iav, viscosity, noo noo, flammability |
Rau batch |
Melt flow indexer, DSC, UL 94 apparatus |
|
Caij nplooj ntoos hlav steel |
Tensile zog, qaug zog kuj, sib sau |
Rau batch |
Tensile tshuab, qaug zog tester |
|
Chaw nres tsheb |
Tswj Parameters |
Ntau zaus |
Txoj kev |
|
Coil winding |
Hloov suav, nro, tsis kam, rwb thaiv tsev |
Txhua chav |
Automated winding nrog tawm tswv yim, ohmmeter |
|
Plunger machining |
Dimensional kam rau ua, nto tiav, hardness |
Txhua 100 units |
CMM, profileometer, hardness tester |
|
Hu rau kev sib dhos |
Alignment, siab, tsis kam, brazing zoo |
Txhua 100 units |
Lub zog ntsuas, micro-ohmmeter, XRF |
|
Lub tsev molding |
Kub, siab, qhov tseeb |
Txhua lub voj voog |
SCADA saib xyuas, SPC kab kos |
|
Sub-assembly |
Kev khiav hauj lwm voltage, stroke, teb lub sij hawm |
Txhua chav |
Automated xeem lub rooj ntev zaum, cov ntaub ntawv logging |
|
Cov khoom kuaj |
Txuj |
Qauv Loj |
|
Kev khiav hauj lwm voltage |
0.85-1.1 × Un (pickup), > 0.2 × Un (dropout rau UVR) |
100% |
|
Lub sijhawm teb (shunt trip) |
<50ms ntawm qhov ntsuas hluav taws xob |
100% |
|
Tiv tauj tiv thaiv |
<50mΩ (ntsuas), <100mΩ ( tswb) |
100% |
|
Dielectric tiv taus voltage |
2 kV AC / 1 min |
100% |
|
Rwb thaiv tsev tsis kam |
> 100MΩ @ 500V DC |
100% |
|
Mechanical ua haujlwm |
10 cycles, du, tsis sticking |
100% |
|
Snap-fit compatibility |
Mating nrog tsim MCB ncej |
100% |
|
Visual & Dimension soj ntsuam |
17.5mm modularity, cim kev ruaj khov |
100% |
|
Hluav taws xob endurance sampling |
1,000 kev ua haujlwm ntawm kev ntsuas load |
AQL 1.0 |
|
Ntim kev ncaj ncees |
Poob xeem, kev vibration (ISTA 3A) |
Rau ntau |
|
Qeb khoom siv |
Tshuab Specification |
Muaj nuj nqi |
Muaj peev xwm |
|
Coil Winding |
CNC winding tshuab (Nittoku / Marsilli) nrog kev tswj nruj |
Precision coil ntau lawm |
20,000 coils / hnub |
|
Stamping & Forming |
60-ton progressive tuag xovxwm (Bruderer) |
Hu rau stamping, caij nplooj ntoos hlav sib sau |
30,000 Cheebtsam / hnub |
|
Txhaj Molding |
80-tuj thermoplastic xovxwm (Arburg) |
Vaj tse, enclosures, DIN rail clips |
10,000 tsev/hnub |
|
Sib dhos Automation |
Robotic cells (ABB/Fanuc) nrog rau lub zeem muag |
Sub-assembly, calibration, kuaj |
5,000 accessories / hnub ib kab |
|
Cov khoom siv kuaj |
Automated accessory xeem lub rooj ntev zaum |
Cov yam ntxwv ua haujlwm, lub sijhawm, kev ua siab ntev |
1,000 units / teev |
|
Mechanical endurance tester |
100,000 lub voj voog pov thawj |
200 units ib txhij |
|
|
EMC chav kuaj |
Kev ntsuas kev tiv thaiv / emission |
100 units / hnub |
|
Yam khoom |
Muaj peev xwm txhua hli |
Standard Lead Time |
Ceev Order Muaj peev xwm |
|
Shunt Trips (tag nrho cov voltages) |
50,000 units |
4-5 lub lis piam |
3 hnub |
|
Undervoltage tso tawm |
20,000 units |
4-5 lub lis piam |
3 hnub |
|
Kev Sib Txuas Sib Txuas |
10,000 units |
4-5 lub lis piam |
3 hnub |
|
Tswb Contacts |
50,000 units |
4-5 lub lis piam |
3 hnub |
|
Lub cev muaj zog ua haujlwm Devices |
50,000 units |
4-5 lub lis piam |
5 hnub |
|
Busbar Systems |
1,000 meters |
4-5 lub lis piam |
3 hnub |
|
Department |
Cov neeg ua haujlwm |
Kev txawj ntse |
Lub luag haujlwm |
|
R & D Engineering |
5 engineers |
Electromagnetic tsim, hu rau physics, IoT kev koom ua ke, kev sib txuas lus wireless |
Kev txhim kho khoom siv tshiab, ntse nta, patent portfolio (30+ patents) |
|
Txheej Txheem Engineering |
15 engineers |
Coil winding automation, precision stamping, yas molding, lean manufacturing |
Kev tsim kho kom zoo, kev txhim kho cov txiaj ntsig (> 99%), txo nqi |
|
Kev xeem & validation |
12 engineers |
IEC 60898 / 60947 Kev ua raws, kev sim siab, EMC, ib puag ncig simulation |
Hom kev soj ntsuam kev sib koom tes, tsis ua hauj lwm tsom xam, kev tswj xyuas ntawv pov thawj |
|
Application Engineering |
10 engineers |
MCB kev koom ua ke, tswj tshuab, BMS / SCADA interface |
Cov neeg siv khoom txhawb nqa, kev tsim qauv, commissioning |
|
Quality Assurance |
25 tus kws tshaj lij |
ISO 9001, IATF 16949, statistical process control, metrology |
Supplier audit, txheej txheem audit, kho kom raug, calibration |
Peb qhov chaw tsim khoom sawv cev20 xyoo kev tshwj xeeb nyob rau hauv qis-voltage Circuit Court tiv thaiv accessories, xa MCB accessories uas tshaj ntiaj teb no cov qauv los ntawm:
Modular kev txawj ntse: Kev nkag siab tob ntawm 17.5mm DIN rail modularity, ua kom muaj kev sib txuam nrog MCBs los ntawm cov tuam txhab loj (Schneider Acti9, ABB System pro M, Siemens Sentron, Hager)
Smart accessory innovation: Proprietary wireless auxiliary contacts thiab lub zog saib xyuas sensors uas hloov cov pa MCBs rau hauv IoT-enabled ntse li yam tsis muaj kev hloov pauv
Vertical kev koom ua ke: Nyob rau hauv tsev coil winding nrog lub tshuab nqus tsev impregnation, precision contact stamping, thiab thermoplastic molding kom ua tiav kev tswj xyuas zoo thiab kev hloov kho sai
Kev ntsuam xyuas infrastructure: $ 2M + nqis peev hauv automated test nrog rau 100,000-cycle mechanical endurance verification, EMC immunity testing, thiab MCB compatibility testing
Ceev ceev customization: Saj zawg zog manufacturing enabling voltage, tiv tauj configuration, thiab kev sib txuas lus raws tu qauv customization nrog 2-lub lim tiam ua lead lub sij hawm