Cov khoom
MCB Tswb thiab Pab Pawg Sib Txuas
  • MCB Tswb thiab Pab Pawg Sib TxuasMCB Tswb thiab Pab Pawg Sib Txuas

MCB Tswb thiab Pab Pawg Sib Txuas

Model:DAB7-FL
Yuav CDADA MCB Tswb thiab Kev Sib Txuas Sib Txuas - dual-function module rau DAB7-63 breakers. Muab 2 tus neeg sib txuas lus sib txuas (auxiliary + tswb) nyob rau hauv ib chav tsev compact. Qhov zoo tshaj plaws rau kev saib xyuas tej thaj chaw deb thiab teeb meem txhaum cai hauv cov vaj huam sib luag. Yooj yim sab laug-sab snap-on nruab. Raws li lub Hoobkas ncaj qha, OEM / tus nqi muag khoom muaj.

CDADA yog cov chaw tsim khoom thiab cov chaw muag khoom nrog 40+ xyoo ntawm kev paub, peb tau pom ntau yam haujlwm uas cov neeg ua haujlwm vaj huam sib luag nco txog qhov tsis txaus ntseeg - txog thaum nws lig dhau lawm. Tias yog vim li cas peb thiaj li tsim CDADA MCB Tswb thiab Pab Pawg Sib Txuas (DAB7-FL): qhov kev daws teeb meem ntse, qhov chaw txuag uas muab rau koj ob lub cim tseem ceeb hauv ib qho module-breaker txoj hauj lwm (ON / OFF) thiab kev mus ncig vim li cas (overload / short-circuit).

Peb Cov Lus Qhia: Yog tias koj qhov kev tswj hwm yuav tsum paub qhov txawv ntawm phau ntawv tawm thiab kev mus ncig ua si, qhov no yog cov khoom siv ntxiv uas koj yuav tsum tau qhia. Tus qauv pabcuam kev sib cuag ib leeg tsis tuaj yeem qhia qhov txawv-tab sis peb tuaj yeem ua tau.

Mcb Alarm And Auxiliary Contact

Dual-Function Design: Ib Module, Ob Lub Teeb Pom Kev

Lub CDADA MCB Tswb & Lub Chaw Pabcuam Tiv Thaiv muaj ob qho kev hloov pauv kev ywj pheej nrog tus neeg siv tshuab ntse ntse:

★ Daj qhov taw qhia ntawm "A": Ob qho kev tiv tauj ua haujlwm pabcuam → teeb liab MCB ON / OFF lub xeev

★ Qhov taw qhia daj ntawm "AL":

★ sab laug kev sib cuag = Pab (ON/OFF raws li txoj cai)

★ Txoj cai tiv tauj = Tswb (tsuas yog qhib thaum MCB mus ncig ua si vim yog qhov txhaum)

★ Qhov no txhais tau tias koj tuaj yeem xaim:

★ Lub teeb ntsuab qhia "lub zog rau"

★ Lub teeb liab lossis PLC tawm tswv yim los ua rau "lub tswb txhaum"

★ Tag nrho los ntawm ib qho ntxiv-rau module ntawm koj DAB7-63 MCB.


Technical Specifications

Parameter

Tus nqi

Tau tshaj MCB

CDADA DAB7-63 series only (1P–4P)

Hu rau hom

2 pawg hloov-tshaj (hloov) hu

Kev ntsuas hluav taws xob



• AC-12: 230V AC, 2A


• AC-15: 230V AC, 1A


• DC-12: 11 0V DC, 0.5A

Mounting txoj hauj lwm

Sab laug ntawm MCB

Kev teeb tsa

Kev ruaj ntseg nrog ob-sided daim kab xev + yeem DIN rail clip

Mechanical Link

Direct tsav ncej coupling - tsis muaj lwm levers xav tau

Tseem ceeb: Cov khoom siv no tsis tuaj yeem siv ib leeg-nws yuav tsum tau txuas ncaj qha mus rau DAB7-63 MCB.


Installation Guide (Los ntawm Peb Field Engineers)

★ Ua raws li cov kauj ruam no kom muaj kev nyab xeeb, txhim khu kev qha:

★ Fais fab OFF lub Circuit Court ua ntej installation.

★ Xaub lub DAB7-FL module mus rau sab laug ntawm DAB7-63 MCB kom txog thaum nws nyem.

★ Ruaj ntseg nrog rau daim kab xev ob sab (rau kev co kuj).

★ Txuas cov xov hlau mus rau 4 lub davhlau ya nyob twg (2 rau ib pab pawg sib cuag):

★ Siv cov khub sab laug rau kev pabcuam (txheej xwm)

★ Siv txoj cai khub rau lub tswb (tawm mus nrhiav)

★ Teem lub xim daj rau "AL" yog tias koj xav tau lub tswb ua haujlwm tsis raug.

★ Kev Xeem: Manually mus rau MCB-tsuas yog lub tswb hu xov tooj yuav tsum hloov lub xeev thaum mus txawv tebchaws txhaum.

★ Cov Lus Qhia Pro: Sau koj cov xov hlau kom meej! Ntau tus kws tshaj lij tsis meej pem nrog lub tswb ceeb toom thaum ua haujlwm.


Thaum twg koj yuav tsum siv qhov no hloov tus txheej txheem pabcuam kev sib cuag?

Scenario

Standard Auxiliary

CDADA Tswb + Pab

Yuav tsum paub yog MCB ON/OFF

✅ Yog

✅ Yog

Yuav tsum paub yog vim li cas nws tripped (fault vs. manual off)

❌ Tsis muaj

✅ Yog

Vaj huam sib luag nrog tej thaj chaw deb SCADA/PLC saib xyuas

Cov ntaub ntawv txwv

Muaj peev xwm kuaj mob

Hluav taws kub tswb los yog kev ruaj ntseg interlock circuits

Tsis txaus

Ua tau raws li cov cai

Cov ntawv thov raug:

★ Data center PDU saib xyuas

★ Hnub ci vaj huam sib luag thawv

★ Industrial tswj vaj huam sib luag

★ Tsev Tswj Xyuas Tsev (BMS)

★ of elevator lossis HVAC kev nyab xeeb circuits

Cov lus nug nquag

Q1: Kuv puas tuaj yeem siv qhov no ntawm cov tsis-CDADA MCBs?

A1: Tsis yog. Lub DAB7-FL yog mechanically thiab dimensionally tsim rau CDADA DAB7-63 breakers. Nws yuav tsis haum Schneider, ABB, lossis Siemens MCBs.


Q2: Lub tswb hu ua haujlwm li cas?

A2: Hauv MCB, ib qho kev sib tw latch txav txawv txav thaum lub sij hawm thermal / magnetic fault trip vs. Lub DAB7-FL kuaj pom qhov sib txawv ntawm qhov sib txawv thiab ua kom lub tswb hu rau thaum muaj kev ua txhaum tiag tiag.


Q3: Kuv puas xav tau ob qho tib si hu xov tooj?

A3: Tsis tas li. Koj tuaj yeem siv qhov kev pabcuam nkaus xwb, tsuas yog lub tswb, lossis ob qho tib si - nyob ntawm koj qhov kev tswj xyuas qhov kev xav. Lub module muab koj yooj yim.


Q4: Nws puas haum rau DC hnub ci daim ntawv thov?

A4: Yog! Nrog rau qhov ntsuas DC-12 ntawm 110V / 0.5A, nws yog qhov zoo tagnrho rau kev saib xyuas cov hlua hnub ci qhov twg koj yuav tsum kuaj xyuas PV array faults remotely.


Q5: Vim li cas thiaj xaiv CDADA tshaj cov khoom lag luam?

A5: Vim peb muab:

● Kev ntxub ntxaug txhaum tiag tiag (tsis yog qhov kev paub qhov chaw xwb)

● Seamless kev koom ua ke nrog DAB7 MCBs—tsis muaj daim hlau adapter

● Factory-tested mechanical coupling – tsis muaj kev ua si lossis tsis muaj teeb meem

● Qhov taw qhia pom pom tseeb (tus chij daj) rau kev txheeb xyuas qhov chaw

● Cov ntawv pov thawj thoob ntiaj teb (CE, CB, RoHS) rau cov haujlwm tsis muaj teeb meem

Daim ntawv kawg los ntawm CDADA R & D

Hauv cov tshuab hluav taws xob niaj hnub no, 'on / off' tsis txaus - koj xav tau kev txawj ntse. Peb MCB Tswb & Pab Pawg Sib Txuas hloov qhov yooj yim breaker rau hauv qhov kev kuaj mob, pab koj tsim cov ntse dua, muaj kev nyab xeeb dua. Thiab vim tias nws tau tsim los ntawm tib pab pawg uas tsim MCB, koj tau txais kev sib koom ua ke zoo tshaj plaws - tsis muaj kev kwv yees. " - Pab pawg tsim khoom CDADA

Npaj kom xaj? Peb muab:

● Kev txo nqi ntau rau cov neeg tsim vaj huam sib luag

● Pre-assembled MCB + DAB7-FL units (txuag kev ua haujlwm)

● Cov duab kos dawb & PLC cov qauv logic

Hot Tags: MCB Tswb thiab Auxiliary Hu rau, Tuam Tshoj, Chaw tsim tshuaj paus, tsum, Hoobkas
Xa lus nug
Tiv tauj Info

Xauv koj cov kev cai hluav taws xob daws teeb meem hauv 24 teev!

Yog vim li cas Nug nrog ib tug Top-Tier Suav Chaw tsim tshuaj paus?

✅ Direct Hoobkas nqi

Txiav tus nqi nruab nrab! Raws li ISO 9001-certified Hoobkas nyob rau hauv Suav teb, peb xa hwm MCCBs, MCBs, thiab hnub ci DC breakers ntawm kev sib tw nqi-rov qab los ntawm CE, KEMA, thiab ASTA ntawv pov thawj.

✅ 40+ Xyoo ntawm OEM / ODM kws tshaj lij

Hloov cov casings, daim ntawv lo, los yog technical specs effortlessly. Peb pab pawg R & D (60+ patents) ua haujlwm:

Kev cai voltage / tam sim no ntsuas

Branded ntim

Fast prototyping (cov qauv hauv 7 hnub)

✅ 3 lab + Cov Khoom Muaj Peev Xwm Txhua Xyoo

Tsis muaj kev txiav txim loj dhau los yog ceev! Peb 52,400㎡ cog lav:

◆ 15-hnub lub sijhawm ua haujlwm rau kev txiav txim ntau

◆ Yooj yim MOQs

◆ nruj ASTM / UL kuaj

✅ Ntiaj teb no ua raws, Tsis muaj Hassle

Peb daws cov teeb meem export rau 45+ lub teb chaws:

RoHS / REACH cov ntaub ntawv

Cov ntawv pov thawj tshwj xeeb hauv cheeb tsam

Hnub ci DC breakers rau EU ntsuab tej yaam num

X
Peb siv cov ncuav qab zib los muab koj cov kev tshawb fawb zoo dua, txheeb xyuas qhov chaw khiav tsheb thiab kho cov ntsiab lus tus kheej. Los ntawm kev siv lub xaib no, koj pom zoo rau peb siv cov ncuav qab zib.Txoj Cai Tswjfwm Ntiag Tug
Tsis lees paubTxais